© Baxi Heating UK Ltd 2012
Neta-tec Plus Combi GA Range
Gas Fired Wall Mounted Condensing
Combination Boiler
Installation & Servicing Instructions
These instructions include the Benchmark Commissioning Checklist
and should be left with the user for safe keeping.
They must be read in conjunction with the Flue Installation Guide.
Vista de página 0
1 2 3 4 5 6 ... 30 31

Resumo do Conteúdo

Página 1 - Neta-tec Plus Combi GA Range

© Baxi Heating UK Ltd 2012Neta-tec Plus Combi GA RangeGas Fired Wall Mounted CondensingCombination BoilerInstallation & Servicing InstructionsThes

Página 2 - Model Range

104.0 Technical Data© Baxi Heating UK Ltd 20120200 400 600 800 1000 12000.511.522.533.54Metre (wg)Flow Rate (l/h)Pump - Available Head055.564.54.1Fl

Página 3 - © Baxi Heating UK Ltd 2012

115.0 Dimensions and Fixings© Baxi Heating UK Ltd 2012360° Orientation Flue Ø 100mmDCBAEGFAt least 1.5°HJHeatingFlow(22mm)Hot WaterOutlet(15mm)GasInle

Página 4 - Legislation

126.0 System Details© Baxi Heating UK Ltd 20126.1 Information1. The Baxi Neta-tec Plus Combi GA Condensing CombinationBoiler is a ‘Water Byelaws Sche

Página 5 - Safe Manual Handling

136.0 System Details© Baxi Heating UK Ltd 2012Fig. 4Fig. 6StopValveDoubleCheckValveDHWMainsInletCHReturnTemporaryLoopStopValveFig. 5Control Box remove

Página 6 - CONTENTS

146.0 System Details© Baxi Heating UK Ltd 2012Fig. 76.8 Domestic Hot Water Circuit (Fig. 7)1. All DHW circuits, connections, fittings, etc. should be

Página 7 - 1.0 Introduction

157.0 Site Requirements© Baxi Heating UK Ltd 20127.1 Location1. The boiler may be fitted to any suitable wall with the fluepassing through an outside

Página 8 - 2.0 General Layout

167.0 Site Requirement© Baxi Heating UK Ltd 20127.4 Gas Supply1. The gas installation should be in accordance with therelevant standards. In GB this i

Página 9 - 3.0 Appliance Operation

177.0 Site Requirements© Baxi Heating UK Ltd 20127.7 Condensate DrainFAILURE TO INSTALL THE CONDENSATEDISCHARGE PIPEWORK CORRECTLY WILL AFFECTTHE RELI

Página 10 - PROPANE ONLY !

187.0 Site Requirements© Baxi Heating UK Ltd 20127.7 Condensate Drain (cont.)11. When discharging condensate into a soil stack or wastepipe the effect

Página 11 - Dimensions

197.0 Site Requirements© Baxi Heating UK Ltd 20127.7 Condensate Drain (cont.)12. A boiler discharge pump is available, ‘MULTIFIT’ part no. 720648301.

Página 12 - 6.0 System Details

2© Baxi Heating UK Ltd 2012Model RangeBaxi Neta-tec Plus Combi 24 GAG.C.No 47-075-64Baxi Neta-tec Plus Combi 28 GAG.C.No 47-075-65Baxi Neta-tec Plus C

Página 13

207.0 Site Requirements© Baxi Heating UK Ltd 20127.8 FlueNOTE: Due to the nature of the boiler a plume of watervapour will be discharged from the flue

Página 14

218.0 Flue Options© Baxi Heating UK Ltd 2012HorizontalFlues(ii)(i)Plume Displacement Kit 60 /100 dia1M Extensions 45° & 93° elbowsare also availab

Página 15 - 7.0 Site Requirements

228.0 Flue Options© Baxi Heating UK Ltd 20128.2 Flue LengthsThe standard horizontal telescopic flue kit allows for lengthsbetween 315mm and 500mm from

Página 16 - 7.0 Site Requirement

239.0 Installation© Baxi Heating UK Ltd 20079.1 Unpacking & Initial PreparationIMPORTANT RISK ASSESSMENT - Before commencing the installationit is

Página 17 - 50mm per metre of pipe run

249.0 Installation© Baxi Heating UK Ltd 2012Fig. 22Pressure Relief ValveDischarge PipeFig. 21Suggested Lifting Pointsshown as shaded areaRemove Sealin

Página 18

25© Baxi Heating UK Ltd 20129.0 Installation9.6 Fitting The FlueHORIZONTAL TELESCOPIC FLUE1. There are two telescopic sections, the TerminalAssembly a

Página 19

26© Baxi Heating UK Ltd 20129.0 Installation 9.6 Fitting the Flue (Cont)10. Remove the flue elbow and insert the flue through thehole in the wall.1

Página 20 - Property Boundary Line

279.0 Installation© Baxi Heating UK Ltd 2012bbrbbkg/y1NL 2NNLRoom ‘StatFused Spur230VFig. 36Fig. 34bbrbbkg/y1NL Frost ThermostatExternal Clock2Pipe Th

Página 21 - 8.0 Flue Options

2811.0 Commissioning© Baxi Heating UK Ltd 201210.0 CommissioningAutomatic AirVentCapFig. 37Pumpbar01234 Control Boxremoved for clarityFig. 38Fig. 39

Página 22

2910.0 Commissioning© Baxi Heating UK Ltd 2012Fig. 40Fig. 41Inlet Gas PressureTest PointDO NOT check gas pressure here10.2 Check the Operational (Work

Página 23 - 9.0 Installation

3Installer Notification Guidelines© Baxi Heating UK Ltd 2012Choose BuildingRegulations NotificationRouteContact your relevant LocalAuthority Building

Página 24

3011.0 Completion & System Draining© Baxi Heating UK Ltd 2012Fig. 42Facia PanelCase Front Panel11.1 Completion1. Replace the case front panel, and

Página 25 - Dimension ‘Y’

3112.0 Servicing© Baxi Heating UK Ltd 201212.1 Performance Safety Check & Annual Servicing1. For reasons of safety and economy, it is recommended

Página 26

4Legislation© Baxi Heating UK Ltd 2012Codes of Practice - refer to the most recent versionIMPORTANT - Installation, Commissioning, Service & Repai

Página 27

5Safe Manual Handling© Baxi Heating UK Ltd 2012GeneralThe following advice should be adhered to, from when first handling the boiler to the final stag

Página 28 - ‘On’ displayed

6© Baxi Heating UK Ltd 2012CONTENTS1.0 Introduction 72.0 General Layout 83.0 Appliance Operation 94.0 Technical Data 105.0 Dimensions and Fixings 116.

Página 29

71.0 Introduction© Baxi Heating UK Ltd 20121.1 Description1. The Baxi Neta-tec Plus Combi GA Range are fully automaticgas fired wall mounted condensin

Página 30 - To change the information

82.0 General Layout© Baxi Heating UK Ltd 20122.1 Layout1. Expansion Vessel2. Boiler Adaptor3. Primary Heat Exchanger4. DHW Plate Heat Exchanger5. Pump

Página 31 - 12.0 Servicing

93.0 Appliance Operation© Baxi Heating UK Ltd 20123.1 Central Heating Mode1. With a demand for heating, the pump circulates waterthrough the primary c