MULTIPOINT BFGas Fired Balanced Flue Water HeaterUser Operating, Installationand Servicing Instructions6 720 607 090 (03.12) JSPlease leave these inst
10 6 720 607 0908. Siting the Flue TerminalSee Fig. 8.8.1 The flue must be installed as specified in BS5440:Part 1.8.2 If the terminal disc
116 720 607 0909. Air Supply9.1 The appliance does not require a separate vent forcombustion air.9.2 The appliance may be installed in an unven
12 6 720 607 09011.4 Unfasten the two retaining screws and lift the caseclear.11.5 Remove the flue hood from the appliance by undoingthe three fixing
136 720 607 090Fig. 16 - Burner pressure test point12. CommissioningBefore commissioning the appliance, the gas installationmust be purged and t
14 6 720 607 09013. Inspection and ServicingFor reasons of safety and economy it is recommend thatthe appliance is serviced annually. The ser
156 720 607 09013.3 Main BurnerDisconnect the pilot gas pipe at the gas valve.Disconnect the pilot gas pipe from the pilot burner andremove from the a
16 6 720 607 09014. Replacement of PartsAny servicing or parts replacement must be carried out by acompetent person. Use only genuine Manufacturer’s P
176 720 607 090outlet connections and lift the heat exchanger clear.Replace the heat exchanger and re-assemble in reverseorder.14.5 Igniter UnitPull o
18 6 720 607 09015.Fault Finding16. Short Parts ListDescription Part Number1Knob and Bezel 5 110 8442Pilot Burner (75) 5 110 8803Pilot Injector (5)
196 720 607 09017. Notes
2 6 720 607 090Natural GasMain Multipoint BFG.C. No 52-467-01User InformationYour Main Multipoint BF is designed to meet all relevantstandard
GENERAL ENQUIRIES (GB)08706 060 780TECHNICAL (GB)08706 049 049SERVICE (GB)08706 096 096LITERATURE REQUEST (GB)08706 060 623TECHNICAL (IE)1850 560
36 720 607 0901. User’s Operating Instructions ...42. General Layout ...
4 6 720 607 0901. User’s Operating InstructionsPilot ignition:1. Depress slide control and hold it in.2. Press theigniter repea-tedly until thepi
56 720 607 0902. General LayoutFig. 3Appliance water flow diagram.Fig. 41 Pilot burner2 Spark electrode3 Thermocouple4 Heat exchanger5 Main burner6 Bu
6 6 720 607 0903. Technical DataTABLE 1 - GENERALTABLE 3 - PERFORMANCETABLE 2 - FLUE DETAILSThe appliance has a permanent pilot.The appliance and flue
76 720 607 0904. Dimensions and FixingsFig. 5
8 6 720 607 0905. General Information5.1 GENERAL INSTALLATIONIf the appliance is to be fitted into a compartment, thecompartment must conform
96 720 607 0907. Siting the Appliance7.1 The appliance is NOT suitable for external installation.7.2 The appliance is NOT suitable for SEDUCTapp