5116154/03
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.
Model 754
INSET LIVE FUEL EFFECT GAS FIRE
Fitted with one of the following fascia.
Amour, Aspect, Aspect Glass,
Eclipse, Fascination, Landscape,
Serenity, Tranquilityor
Visia
(GC No. 32-032-59)
We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our
Baxi Fires Division Technical
Helpline will be pleased to help.
Telephone 08706 061 065 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 8706 061 065.
THIS APPLIANCE IS FOR USE WITH
NATURAL GAS (G20).
WHEN CONVERTED USING
CONVERSION KIT NO. 05754M1 THE
‘FASCINATION’ MODEL IS FOR USE
WITH PROPANE GAS (G31).
THIS APPLIANCE IS SUITABLE ONLY
FOR INSTALLATION IN THE UNITED
KINGDOM (GB) AND THE REPUBLIC
OF IRELAND (IE).
INSTALLER: Please leave this guide with the
Vista de página 0
1 2 3 4 5 6 ... 41 42

Resumo do Conteúdo

Página 1 - Model 754

5116154/03INSTALLER GUIDE© Baxi Heating U.K. Limited 2007.Model 754INSET LIVE FUEL EFFECT GAS FIREFitted with one of the following fascia.Amour, Aspec

Página 2

requirements of the current edition ofBS EN 1856 Part 1 or BS715. Thedimensions of the flue box mustconform to those shown in figure 2.4.2.3 A precast

Página 3

materials to be used are stainless steel or aluminium as specified in BS EN 1856 Part1 or BS715. The liner must be sealed to the surrounding area abov

Página 4

4.11 Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected byheat. They may scorch or become discoloured when close to a heati

Página 5

4.16 If the appliance is to be fittedagainst a wall with combustiblecladding, the cladding must beremoved from the area covered bythe fascia. The clad

Página 6

4.20 The minimum allowable distance from the outside of the appliance fascia to acorner wall having combustible material or any other combustible surf

Página 7

Page 15INSTALLER GUIDE© Baxi Heating U.K. Limited 2007.KeyDescriptionModelAmour AspectEclipseFascinationLandscape& SerenityVisiaTranquility &A

Página 8

5. PACK CONTENTS1 Burner & Hotbox Unit1 Nut & olive for 8mm inlet pipe1 Inlet ‘T’ Connector1 Flue restrictor plate2 Screws (For flue restricto

Página 9

Page 17INSTALLER GUIDE© Baxi Heating U.K. Limited 2007.Figure 6. Pack contents continued

Página 10 - INSTALLER GUIDE

Carefully remove all the contents. Take special care in handling the ceramic fuel effects.Check that all the listed parts are present and in good cond

Página 11

be fitted against a wall with combustible cladding, the cladding must be removed fromthe area covered by the fascia. The cladding must also not touch

Página 12

© Baxi Heating U.K. Limited 2007.All rights reserved. No part of this publication may be reproduced in any material form(including photocopying), stor

Página 13

7. IGNITION CHECKBefore attempting to install, it isworth checking that the ignitionsystem performs satisfactorily.Set the control knob to the offposi

Página 14

9. PREPARING APPLIANCE FOR INSTALLATION1. Detach the spillage plate from the hotbox by removingthe four screws (See figure 9).2. Remove the protective

Página 15

10. Fit the two “U” section seals to thebottom edges of the hotbox side flanges (Seefigure 12).11. It is important that the grommetsupplied in the loo

Página 16

supplied with the fire. This will need to befitted to the outer rear edges of the sideand top flanges of the hotbox. Cut a485mm length of foam seal. B

Página 17

10.2 Method 2 - Cable retentionand floor fixing.1. Make sure that the relevant areas atthe fireplace back or floor are soundenough to take the eyebolt

Página 18

7. Place the hotbox fully back into the fireplace opening so that it is sealed against thefireplace front surround.8. Drill a hole into the fireplace

Página 19

10.3 Sealing floor front - all installations.Using the floor sealing tape supplied, seal thebottom of the hotbox to the fireplace and hearthfloor (See

Página 20

11.3 Preliminary burner checks.Some burner operations can be checked at this stage. Checking now will mean that lessdisassembly will be required if an

Página 21

11.5 Fitting the lower hotbox baffle to the‘Fascination’model.The lower hotbox baffle is supplied for use whenfitting the ‘Fascination’ model into ele

Página 22

13.1.2 Operating the burner.Turn the control knob anti-clockwise to ‘HIGH’ (Depress the knob slightly to get pastthe pilot ignition position). The mai

Página 23

Safety First.Baxi Fires Division fires are CE Approved and designed to meet the appropriate BritishStandards and Safety Marks.Quality and Excellence.A

Página 24

13.3 Flame supervision and spillage monitoring system.This pilot unit includes a system that will automatically shut off the gas supply if thepilot fl

Página 25

3. The fascia decorative trim ismade up of four sections. Abottom and top section of equallength and two shorter sectionsof equal length that are the

Página 26

14.2 Fitting the Landscape, Visia and Serenity fascia.1. Supplied with the fire are twofascia securing brackets and twomachine screws. Secure thebrack

Página 27

14.3 Fitting the trims to the Fascinationfascia.1. Remove any protective film from thefascia.2. Lay the fascia frame on a flat surface withits front f

Página 28

14.4Fitting the Glass panel to the ‘Fascination’ , ‘Tranquility’ and ‘Aspect Glass’fascia (See figure 38).1. Supplied with the trim packare four cylin

Página 29

Important: The spacers provided with the trim pack must always be fitted. Neverreduce the depth of the spacers in any way. Always replace the spacers

Página 30

15. FINAL REVIEW1.Visually inspect the appliance. Clean off any marks incurred during installation. Thefire should be ‘off’ and allowed to cool comple

Página 31

it will disappear after a short period of use.9.Inform the customer that the Serial number for the appliance is located on thedata label located behin

Página 32

16.1 To remove the fascia.Amour, Aspect, Aspect Glass, Eclipse, Tranquilityand Fascination models.1. Eclipse model only- Remove the upper fascia trim

Página 33

16.2 To remove the burner unit.1. Remove the fascia as in section 16.1.2. Remove the ceramic fuel effect pieces.3. Detach the spillage plate from the

Página 34

CONTENTSSection Heading Page1. SAFETY 52. ACCESSORY LIST 53. APPLIANCE DATA 64. GENERAL INSTALLATION REQUIREMENTS 85. PACK CONTENTS 166. FIREPLAC

Página 35

16.3 To remove the pilot unit.1. Remove the burner unit (See section 16.2).2. If lying the burner on its back, ensure that the worksurface is suitably

Página 36

16.5 To remove the piezo generator.1. Remove the gas valve as section 16.4.2. Make sure that the tap is in the off position.3. Remove the circlip hold

Página 37

16.8 To remove the main burner injector.(See figure 51).1. Remove the burner (See section 16.7).2. Remove the burner clamping screw (See figure 51)3.

Página 38

1. SAFETYInstallerBefore continuing any further with the installation of this appliance please read the following guide to manual handling:! The appr

Página 39

3. APPLIANCE DATA* When converted using conversion kit number 05754M1.The appliance data label is located on a plate at the base of the fire. This can

Página 40

The efficiency of this appliance has been measured as specified in BS 7977 - 1 and theresult is as below :ModelEfficiency % (Gross)Amour, Aspect, Ecli

Página 41

4. GENERAL INSTALLATION REQUIREMENTS4.1 The installation must be in accordance with these instructions.For the user’s protection, in the United Kingdo

Página 42

area and clearancedimensions are shown infigure 1.4.2.1.1 ‘Hole-in-the-wall’installations.! It is recommended that ahearth should beinstalled as in fi