5116154/03INSTALLER GUIDE© Baxi Heating U.K. Limited 2007.Model 754INSET LIVE FUEL EFFECT GAS FIREFitted with one of the following fascia.Amour, Aspec
requirements of the current edition ofBS EN 1856 Part 1 or BS715. Thedimensions of the flue box mustconform to those shown in figure 2.4.2.3 A precast
materials to be used are stainless steel or aluminium as specified in BS EN 1856 Part1 or BS715. The liner must be sealed to the surrounding area abov
4.11 Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected byheat. They may scorch or become discoloured when close to a heati
4.16 If the appliance is to be fittedagainst a wall with combustiblecladding, the cladding must beremoved from the area covered bythe fascia. The clad
4.20 The minimum allowable distance from the outside of the appliance fascia to acorner wall having combustible material or any other combustible surf
Page 15INSTALLER GUIDE© Baxi Heating U.K. Limited 2007.KeyDescriptionModelAmour AspectEclipseFascinationLandscape& SerenityVisiaTranquility &A
5. PACK CONTENTS1 Burner & Hotbox Unit1 Nut & olive for 8mm inlet pipe1 Inlet ‘T’ Connector1 Flue restrictor plate2 Screws (For flue restricto
Page 17INSTALLER GUIDE© Baxi Heating U.K. Limited 2007.Figure 6. Pack contents continued
Carefully remove all the contents. Take special care in handling the ceramic fuel effects.Check that all the listed parts are present and in good cond
be fitted against a wall with combustible cladding, the cladding must be removed fromthe area covered by the fascia. The cladding must also not touch
© Baxi Heating U.K. Limited 2007.All rights reserved. No part of this publication may be reproduced in any material form(including photocopying), stor
7. IGNITION CHECKBefore attempting to install, it isworth checking that the ignitionsystem performs satisfactorily.Set the control knob to the offposi
9. PREPARING APPLIANCE FOR INSTALLATION1. Detach the spillage plate from the hotbox by removingthe four screws (See figure 9).2. Remove the protective
10. Fit the two “U” section seals to thebottom edges of the hotbox side flanges (Seefigure 12).11. It is important that the grommetsupplied in the loo
supplied with the fire. This will need to befitted to the outer rear edges of the sideand top flanges of the hotbox. Cut a485mm length of foam seal. B
10.2 Method 2 - Cable retentionand floor fixing.1. Make sure that the relevant areas atthe fireplace back or floor are soundenough to take the eyebolt
7. Place the hotbox fully back into the fireplace opening so that it is sealed against thefireplace front surround.8. Drill a hole into the fireplace
10.3 Sealing floor front - all installations.Using the floor sealing tape supplied, seal thebottom of the hotbox to the fireplace and hearthfloor (See
11.3 Preliminary burner checks.Some burner operations can be checked at this stage. Checking now will mean that lessdisassembly will be required if an
11.5 Fitting the lower hotbox baffle to the‘Fascination’model.The lower hotbox baffle is supplied for use whenfitting the ‘Fascination’ model into ele
13.1.2 Operating the burner.Turn the control knob anti-clockwise to ‘HIGH’ (Depress the knob slightly to get pastthe pilot ignition position). The mai
Safety First.Baxi Fires Division fires are CE Approved and designed to meet the appropriate BritishStandards and Safety Marks.Quality and Excellence.A
13.3 Flame supervision and spillage monitoring system.This pilot unit includes a system that will automatically shut off the gas supply if thepilot fl
3. The fascia decorative trim ismade up of four sections. Abottom and top section of equallength and two shorter sectionsof equal length that are the
14.2 Fitting the Landscape, Visia and Serenity fascia.1. Supplied with the fire are twofascia securing brackets and twomachine screws. Secure thebrack
14.3 Fitting the trims to the Fascinationfascia.1. Remove any protective film from thefascia.2. Lay the fascia frame on a flat surface withits front f
14.4Fitting the Glass panel to the ‘Fascination’ , ‘Tranquility’ and ‘Aspect Glass’fascia (See figure 38).1. Supplied with the trim packare four cylin
Important: The spacers provided with the trim pack must always be fitted. Neverreduce the depth of the spacers in any way. Always replace the spacers
15. FINAL REVIEW1.Visually inspect the appliance. Clean off any marks incurred during installation. Thefire should be ‘off’ and allowed to cool comple
it will disappear after a short period of use.9.Inform the customer that the Serial number for the appliance is located on thedata label located behin
16.1 To remove the fascia.Amour, Aspect, Aspect Glass, Eclipse, Tranquilityand Fascination models.1. Eclipse model only- Remove the upper fascia trim
16.2 To remove the burner unit.1. Remove the fascia as in section 16.1.2. Remove the ceramic fuel effect pieces.3. Detach the spillage plate from the
CONTENTSSection Heading Page1. SAFETY 52. ACCESSORY LIST 53. APPLIANCE DATA 64. GENERAL INSTALLATION REQUIREMENTS 85. PACK CONTENTS 166. FIREPLAC
16.3 To remove the pilot unit.1. Remove the burner unit (See section 16.2).2. If lying the burner on its back, ensure that the worksurface is suitably
16.5 To remove the piezo generator.1. Remove the gas valve as section 16.4.2. Make sure that the tap is in the off position.3. Remove the circlip hold
16.8 To remove the main burner injector.(See figure 51).1. Remove the burner (See section 16.7).2. Remove the burner clamping screw (See figure 51)3.
1. SAFETYInstallerBefore continuing any further with the installation of this appliance please read the following guide to manual handling:! The appr
3. APPLIANCE DATA* When converted using conversion kit number 05754M1.The appliance data label is located on a plate at the base of the fire. This can
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and theresult is as below :ModelEfficiency % (Gross)Amour, Aspect, Ecli
4. GENERAL INSTALLATION REQUIREMENTS4.1 The installation must be in accordance with these instructions.For the user’s protection, in the United Kingdo
area and clearancedimensions are shown infigure 1.4.2.1.1 ‘Hole-in-the-wall’installations.! It is recommended that ahearth should beinstalled as in fi