Model 754
INSET LIVE FUEL EFFECT GAS FIRE
Fitted with one of the following fascia.
Amour, Aspect, Aspect Glass,
Eclipse, Fascination, Landscape,
Serenity, Tranquility
or
Visia
(GC No. 32-032-59)
INSTALLER: Please leave this guide with the owner
INSTALLATION AND OWNER GUIDE
We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our
Valor Fires Technical Helpline will
be pleased to help.
Telephone 0844 8711 565 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 844 8711 565.
Vista de página 0
1 2 3 4 5 6 ... 59 60

Resumo do Conteúdo

Página 1 - Model 754

5131652/01© Baxi Heating U.K. Limited 2008.Model 754INSET LIVE FUEL EFFECT GAS FIREFitted with one of the following fascia.Amour, Aspect, Aspect Glass

Página 2

4.2.1.1 ‘Hole-in-the-wall’ installations. It is recommended thata hearth should beinstalled as in figure 1.If a hearth is not fitted,the fire must be

Página 3

4.2.2 To a fireplace incorporating ametal flue box complying with theconstructional requirements of thecurrent edition of BS EN 1856 Part 1or BS715.

Página 4

materials to be used are stainless steel or aluminium as specified in BS EN 1856Part 1 or BS715. The liner must be sealed to the surrounding area abov

Página 5

4.12 This appliance must not be installed in any room that contains a bath or showeror where steam is regularly present.4.13 An extractor fan may only

Página 6

increased by at least 2mm all round.If the cladding projects forward fromthe fixing plane of the fire theclearance at the top of theappliance must be

Página 7

Page 15© Baxi Heating U.K. Limited 2008.Figure 5. Appliance dimensions and clearances - SEE TABLE ON NEXT PAGE (Fascia may differ fromthat shown)INSTA

Página 8

Page 16© Baxi Heating U.K. Limited 2008.INSTALLER GUIDEKey DescriptionModelAmourAspect Eclipse FascinationLandscape& SerenityVisiaTranquility &am

Página 9

5. PACK CONTENTS1 Burner & Hotbox Unit.1 Nut & olive for 8mm inlet pipe.1 Inlet ‘T’ Connector.1 Flue restrictor plate.2 Screws (For flue restr

Página 10 - INSTALLER GUIDE

Page 18© Baxi Heating U.K. Limited 2008.INSTALLER GUIDEFigure 6. Pack contents continued

Página 11

Carefully remove all the contents. Take special care in handling the ceramic fueleffects. Check that all the listed parts are present and in good cond

Página 12

© Baxi Heating U.K. Limited 2008.All rights reserved. No part of this publication may be reproduced in any material form(including photocopying), stor

Página 13

the area covered by the fascia. The cladding must also not touch the fascia (Seefigure 4). We suggest that the actual fascia is used as a template to

Página 14

7. IGNITION CHECKBefore attempting to install, it isworth checking that the ignitionsystem performs satisfactorily.Set the control knob to the offposi

Página 15

9. PREPARING APPLIANCE FOR INSTALLATION1. Detach the spillage plate from the hotbox byremoving the four screws (See figure 9).2. Remove the protective

Página 16

10. Fit the two “U” section seals to thebottom edges of the hotbox side flanges(See figure 12).11. It is important that the grommetsupplied in the loo

Página 17

fitted to the outer rear edges of the sideand top flanges of the hotbox. Cut a485mm length of foam seal. Be carefulnot to stretch the seal when measur

Página 18

10.2 Method 2 - Cable retentionand floor fixing.1. Make sure that the relevant areasat the fireplace back or floor aresound enough to take the eyebolt

Página 19

7. Place the hotbox fully back into the fireplace opening so that it is sealed againstthe fireplace front surround.8. Drill a hole into the fireplace

Página 20

10.3 Sealing floor front - all installations.Using the floor sealing tape supplied, seal thebottom of the hotbox to the fireplace and hearthfloor (See

Página 21

11.3 Preliminary burner checks.Some burner operations can be checked at this stage. Checking now will mean thatless disassembly will be required if an

Página 22

11.5 Fitting the lower hotbox baffle to the‘Fascination’model.The lower hotbox baffle is supplied for use whenfitting the ‘Fascination’ model into ele

Página 23

Safety First.Valor Fires fires are CE Approved and designed to meet the appropriate BritishStandards and Safety Marks.Quality and Excellence.All Valor

Página 24

13.1.2 Operating the burner.Turn the control knob anti-clockwise to ‘HIGH’ (Depress the knob slightly to get pastthe pilot ignition position). The mai

Página 25

13.3 Flame supervision and spillage monitoring system.This pilot unit includes a system that will automatically shut off the gas supply if thepilot fl

Página 26

3. The fasciadecorative trim ismade up of foursections. A bottomand top section ofequal length andtwo shortersections of equallength that are theside

Página 27

8. Locate the top trim as infigure 31.14.2 Fitting the Landscape, Visia and Serenity fascia.1. Supplied with the fire are twofascia securing brackets

Página 28

4. The lower inner sides of the fascia should sit on top of the fascia securing brackets.The fascia will need to be re-positioned if the fascia sides

Página 29

14.4 Fitting the Glass panel to the ‘Fascination’ , ‘Tranquility’ and ‘Aspect Glass’fascia (See figure 39).1. Supplied with the trim packare four cyli

Página 30

Important: The spacersprovided with the trim packmust always be fitted.Never reduce the depth ofthe spacers in any way.Always replace thespacers with

Página 31

3. Advise the customer how to operate the appliance. Point out that lightinginstruction details are on the metal plate attached at the bottom of the a

Página 32

16. SERVICING & PARTS REPLACEMENT Always turn off the gas supply before commencing any servicing (Theappliance inlet “T” connector incorporates a

Página 33

16.1 To remove the fascia.(Amour, Aspect, Aspect Glass, Eclipse, Tranquilityand Fascination models).1. Eclipse model only- Remove the upper fascia tr

Página 34

Page 4© Baxi Heating U.K. Limited 2008.INSTALLER GUIDEINSTALLER GUIDEFOR OWNER GUIDE SEE PAGES 44 TO 59

Página 35

16.2 To remove the burner unit.1. Remove the fascia as in section 16.1.2. Remove the ceramic fuel effect pieces.3. Detach the spillage plate from the

Página 36

16.3 To remove the pilot unit.1. Remove the burner unit (See section 16.2).2. If lying the burner on its back, ensure that the worksurface is suitably

Página 37

16.5 To remove the piezo generator.1. Remove the gas valve as section 16.4.2. Make sure that the tap is in the off position.3. Remove the circlip hold

Página 38

16.8 To remove the main burner injector.(See figure 51).1. Remove the burner (See section 16.7).2. Remove the burner clamping screw (See figure51)3. U

Página 39

Page 44© Baxi Heating U.K. Limited 2008.OWNER GUIDEOWNER GUIDEFOR WARRANTY AND SERVICE INFORMATIONSEE PAGES 55 TO 59

Página 40

LIST OF CONTENTSSection PageSAFETY 46APPLIANCE DIMENSIONS 47GAS CONSUMPTION 49OPERATING YOUR FIRE 50The Oxysafe flame sensing and flue blockage saf

Página 41

SAFETYDo have the fire installed by a competent person. In the United Kingdom, installationmust be in accordance with the latest edition of the Gas Sa

Página 42

by heat. They may, therefore, scorch or become discoloured when close to a heatingappliance. Please bear this in mind whenever you are considering red

Página 43

Page 48© Baxi Heating U.K. Limited 2008.OWNER GUIDEKey DescriptionModelAmourAspectEclipseFascinationLandscape& SerenityVisiaTranquility &Aspec

Página 44 - OWNER GUIDE

GAS CONSUMPTIONModel 754 when fitted with Amour, Aspect, Eclipse, Landscape, Serenity andVisia fascia.Has a maximum natural gas input of 5.1kW (Gross)

Página 45

CONTENTSSection Heading PageINSTALLER GUIDE 4 - 43OWNER GUIDE 44 - 591. SAFETY 62. ACCESSORY LIST 63. APPLIANCE DATA 74. GENERAL INSTALLATION REQUI

Página 46

OPERATING YOUR FIREThe Oxysafe flame sensing and flue blockage safety system.For your safety, this appliance is fitted with a flue blockage safety dev

Página 47

Eclipse and Fascination models.To gain access to the control knob lower thebottom front cover. To do this, support the topedges of the lower front cov

Página 48

the knob reaches the “HIGH” position.Note:i) If the flames go out while setting the control, repeat the full lighting procedure.If the flames repeated

Página 49

CLEANING YOUR FIRETo maintain the high performance and quality finish of your fire please follow theseguidelines: Before attempting to clean the fir

Página 50

 In the unlikely event of soot forming, light coatings will usually be burnt off duringthe normal operation of the fire. Should any soot accumulat

Página 51

MAINTENANCERegular maintenance.In order to achieve and maintain high levels of personal safety and performanceefficiency, it is essential that the ope

Página 52

What you need to do if you experience a problem with the operation of the fire:  You should always contact your installer first, because the cause o

Página 53

Page 57© Baxi Heating U.K. Limited 2008.OWNER GUIDE

Página 54

Page 58© Baxi Heating U.K. Limited 2008.Installer Details (Block Capitals)Installer NameCorgi Registration Number.Company Name.Company AddressCompany

Página 55

Page 59© Baxi Heating U.K. Limited 2008.Brand (Please tick)Baxi Valor Wonderfire Other...D D M M Y YDate of InstallationFascia

Página 56

1. SAFETYInstallerBefore continuing any further with the installation of this appliance please read the following guide to manual handling: The appr

Página 57

© Baxi Heating U.K. Limited 2008.

Página 58

3. APPLIANCE DATA* When converted using conversion kit number 05754M1.The appliance information label is located on a plate at the base of the fire. T

Página 59

The efficiency of this appliance has been measured as specified in BS 7977 - 1 andthe result is as below :ModelEfficiency % (Gross)Amour, Aspect, Ecli

Página 60

4. GENERAL INSTALLATION REQUIREMENTS4.1 The installation must be in accordance with these instructions.For the user’s protection, in the United Kingdo